FLOWSIC600 Ultrasonic Flowmeter
Brand: Endress+HauserThe FLOWSIC600 is an ultrasonic flowmeter that sets the standard in its market segment. The design shows that it is geared towards the harsh conditions of the industry. Thanks to its compact design with integrated cable routing, the measuring system is durable, fail-safe, low-maintenance, and exhibits long-term stability. The FLOWSIC600 has extensive diagnostic options that allow faults to be detected before the measurement is affected and offers process monitoring based on the speed of sound.
- Process gases flow metering
- Industry gas metering CO2, H2, Air, N2, O2, NH3, Ethylene, Helium, Argon
- Internal allocation measurement
- For gases with high H2S component such as sour gas or biogas
Device properties:
- Highly efficient ultrasonic transducer - up to gas temperatures of +105 °C and pressures up to 250 bar
- Direct path layout
- Intelligent self-diagnostics
- Compact, robust design
- Integrated log book and data logger
- Large measuring range 1:120
- Bidirectional measurement
- Low power consumption: <1 W
Specifications
Brand
Measuring Principle
- Ultrasonic transit time difference measurement
Measured Variables
- Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
Measuring Medium
- Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content
Repeatability
- < 0.1 % of the measured value
Accuracy
- 2-path version ≤ ± 1 %
- 4-path version ≤ ± 0.5 %
- Typical accuracy, see application specific data for detailed information
Medium Temperature Range
Operating Pressure
Nominal Pipe Size
Metrological Approvals & Certificates
Hazardous Area Approvals
Digital Outputs
Digital communication
for Authorized Channel Partners